Serial Status Register (Scssr1) - Hitachi SH7750 series Hardware Manual

Superh risc engine
Hide thumbs Also See for SH7750 series:
Table of Contents

Advertisement

15.2.7

Serial Status Register (SCSSR1)

Bit:
Initial value:
R/W:
Note: * Only 0 can be written, to clear the flag.
SCSSR1 is an 8-bit register containing status flags that indicate the operating status of the SCI,
and multiprocessor bits.
SCSSR1 can be read or written to by the CPU at all times. However, 1 cannot be written to flags
TDRE, RDRF, ORER, PER, and FER. Also note that in order to clear these flags they must be
read as 1 beforehand. The TEND flag and MPB flag are read-only flags and cannot be modified.
SCSSR1 is initialized to H'84 by a power-on reset or manual reset, in standby mode, and in the
module standby state.
Bit 7—Transmit Data Register Empty (TDRE): Indicates that data has been transferred from
SCTDR1 to SCTSR1 and the next serial transmit data can be written to SCTDR1.
Bit 7: TDRE
0
1
7
6
TDRE
RDRF
1
0
R/(W)*
R/(W)*
Description
Valid transmit data has been written to SCTDR1
[Clearing conditions]
When 0 is written to TDRE after reading TDRE = 1
When data is written to SCTDR1 by the DMAC
There is no valid transmit data in SCTDR1
[Setting conditions]
Power-on reset, manual reset, standby mode, or module standby
When the TE bit in SCSCR1 is 0
When data is transferred from SCTDR1 to SCTSR1 and data can be
written to SCTDR1
5
4
ORER
FER
0
0
R/(W)*
R/(W)*
3
2
PER
TEND
0
1
R/(W)*
R
Rev. 4.0, 04/00, page 515 of 850
1
0
MPB
MPBT
0
0
R
R/W
(Initial value)