Sigtimer - Cisco ATA186-I1 Administrator's Manual

Analog telephone adaptor
Hide thumbs Also See for ATA186-I1:
Table of Contents

Advertisement

Chapter 5
Parameters and Defaults

SigTimer

Description
This parameter controls various timeout values for the Cisco ATA.
this parameter.
Value Type
Bitmap
Default
0x00000064
Voice Configuration Menu Access Code
318
Related Parameter
CallWaitTone, page 5-36
Table 5-3
SigTimer Parameter Bit Definitions
Bit Number
Definition
0-7
Call waiting period—The period between each burst of call-waiting tone.
Range: 0 to 255 in 0.1 seconds
Default: 100 (0x64=100 seconds)
8-15
Not used for SCCP.
16-21
Reserved—Should be set to 0.
22-25
Reorder delay—The amount of time before the Cisco ATA plays a fast-busy tone to its FXS port after the
far-end party disconnects a call.
Range: Values of 1 to 14 designate the number of seconds of the reorder delay; a value of 15 means that the
Cisco ATA will not play a fast-busy tone.
Default value: 0 (a four-second reorder delay)
26-27
Minimum hook flash time—The minimum on-hook time required for a hook flash event.
Range: 0 to 3
Default: 0 (60 ms)
Other possible values: 1=100 ms, 2=200 ms, 3=300 ms.
28-31
Maximum hook flash time—The maximum on-hook time allowed for a hook flash event.
Range: 0 to 15
Default: 0 (1000 ms)
Other possible values: 1=100 ms, 2=200 ms, 3=300 ms, 4=400 ms, 5=500 ms, 6=600 ms, 7=700 ms, 8=800
ms, 9=900 ms, 10=1000 ms, 11=1100 ms, 12=1200 ms, 13=1300 ms, 14=1400 ms, 15=1500 ms.
OL-4652-01
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator's Guide for SCCP (version 3.0)
Operational Parameters
Table 5-3
contains bit definitions of
5-23