Featuretimer2; Sigtimer - Cisco ATA186-I2 Administrator's Manual

Analog telephone adaptor
Table of Contents

Advertisement

Chapter 5
Parameters and Defaults

FeatureTimer2

Description
This parameter provides configurable timing values for various Cisco ATA features, as described below:
To disable this feature, set the value of bits 0-7 to 0.
Note
Value Type
Bitmap
Default
0x0000001e
Voice Configuration Menu Access Code
361

SigTimer

Description
This parameter controls various timeout values.
parameter.
Value Type
Bitmap
Default
0x01418564
Voice Configuration Menu Access Code
318
OL-4804-01
Bits 0-7—Maximum time that the Ethernet connection can be disconnected before the Cisco ATA
automatically reboots.
Range: 0 - 255
Factor: one-second increments
Values: 0 - 255 seconds
Default: 30 (equals 30 seconds)