Using System Diagnostics
Example—Cisco ATA Configuration Update Message
<30>00:00:01 192.168.3.237 [03]:ATA Config Update OK
This message includes the following information:
Priority=30, which means that the facility value is 3 (system daemon) and the severity value is 6 (
informational messages). You can derive this information from RFC-3164.
The time offset of the message is 00:00:01, which means that the most recent Cisco ATA reset was
one second earlier.
The tag value is 03, which corresponds to Cisco ATA configuration-update messages. This is
derived from
This message shows indicates the status of the Cisco ATA configuration-file update.
Example—System Reboot Message
<31>00:00:00 192.168.3.220 [04]:Reboot from ata00012d010829(HWVersion1)
@192.168.3.220 (warmStart:0)
This message includes the following information:
Priority=31, which means that the facility value is 3 (system daemon) and the severity value is 7
(debug-level messages). You can derive this information from RFC-3164.
The time offset of the message is 0.
The tag value is 04, which corresponds to system-reboot messages. This is derived from
on page
This message includes the MAC address, hardware version and IP address of the Cisco ATA, and
the reason for the reboot.
Example—Cisco ATA Event Messages
<142>00:00:40 192.168.3.169 [09]:[0]OFFHOOK
<142>00:00:43 192.168.3.169 [09]:[0]ONHOOK
<142>00:01:35 192.168.3.169 [09]:[0]OFFHOOK
<142>00:01:50 192.168.3.169 [09]:[0]DTMF 2 , insum:830200
<142>00:01:50 192.168.3.169 [09]:[0]DTMF 2 , insum:854313
<142>00:01:50 192.168.3.169 [09]:[0]DTMF 1 , insum:868411
<142>00:01:50 192.168.3.169 [09]:[0]DTMF 2 , insum:861215
<142>00:01:50 192.168.3.169 [09]:[0]DTMF 0 , insum:858638
<142>00:01:51 192.168.3.169 [09]:[0]DTMF # , insum:845590
<142>00:01:51 192.168.3.169 [09]:[0]CLIP 22120
These messages include the following information:
Priority=142, which means that the facility value is 17 (local use 1) and the severity value is 6
(informational messages). You can derive this information from RFC-3164.
The time offset of the first message is 40 seconds.
The tag value is 09, which corresponds to Cisco ATA event messages. This is derived from
Table 5-7 on page
The ch (active line of the Cisco ATA) is line 0, which is the Phone 1 port of the Cisco ATA.
The messages include DTMF debugging (showing the key and the insum number), on/off hook,
Caller ID (CLIP/CLIR) and the callee number.
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator's Guide for SCCP (version 3.0)
8-8
Table 5-7 on page
5-39.
5-39.
5-39.
Chapter 8
Troubleshooting
Table 5-7
OL-4652-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ata186-i2-aAta 186Ata 188

Table of Contents