Chapter 5
Parameters and Defaults

ConnectMode

Description
This parameter is a 32-bit bitmap to control the connection mode of the selected call signaling protocol.
Table 5-2
Value Type
Bitmap
Default
0x90000400
Voice Configuration Menu Access Code
311
Related Parameters
Table 5-2
ConnectMode Parameter Bit Definitions
Bit Number
Definition
0
0—Use the Cisco CallManager Cisco IP Telephony Locale Installer feature for the configuration of
Cisco ATA tone parameters. For more information, see the
Option" section on page
The version of Cisco CallManager must be 3.3(3) or later and must contain Cisco IP Telephony
Note
Locale Installer.
1—Use the Cisco ATA call-progress tone parameter configuration to override the Cisco CallManager tone
configuration parameters. For more information, see the
page
5-26.
Default: 0
1
Reserved.
2
0—Use the dynamic payload type 126/127 as the RTP payload type (fax pass-through mode) for G.711
µ-law/G.711 A-law.
1—Use the standard payload type 0/8 as the RTP payload type (fax pass-through mode) for G.711
µ-law/G.711 A-law.
Default: 0
3-6
Reserved.
7
0/1—Disable/enable fax pass-through redundancy.
Default: 0
8-12
Specifies the fax pass-through NSE payload type. The value is the offset to the NSE payload base number of
96. The valid range is 0-23; the default is 4.
For example, if the offset is 4, the NSE payload type is 100.
OL-4652-01
provides bit definitions for this parameter.
AudioMode, page 5-16
LBRCodec, page 5-13
4-5.
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator's Guide for SCCP (version 3.0)
"Using the Cisco IP Telephony Network Locale
"Tone Configuration Parameters" section on
Operational Parameters
5-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ata186-i2-aAta 186Ata 188

Table of Contents