Initial System Configuration
Step 6: Configuring the RDR Formatter Destination
The SCE 2000 passes Raw Data Records (RDRs) to an external collection system via the RDR-
Formatter. In order for the data to reach the correct location, the IP address of the external
collection system and its port number must be configured.
To configure the RDR-formatter destination, complete the following steps:
Step 1
Would you like to enter the RDR-formatter configuration menu? [no]: y
Type y and press Enter.
The RDR-formatter destination dialog begins.
Step 2
Enter RDR-formatter destination's IP address:
Note that there is no default for this parameter.
Step 3
Note that there is no default for this parameter.
Enter RDR-formatter destination's TCP port number:
E
XAMPLE
Following is a sample RDR-formatter configuration dialog, assigning the IP address and TCP port
number.
Would you like to enter the RDR-formatter configuration menu? [no]: y
Enter RDR-formatter destination's IP address: 10.1.1.230
Enter RDR-formatter destination's TCP port number: 33000
SCE 2000 4xGBE Installation and Configuration Guide
5-12
Chapter 5
Connecting the Management Interfaces and Performing Initial System Configuration
Enter the RDR formatter configuration menu.
Type the IP address of the RDR-formatter destination and press Enter.
Type the TCP port number of the RDR-formatter destination and press Enter.
:
OL-7824-02