Installing the SCE 2000 Platform
To connect the grounding cable to the chassis grounding connector on the SCE 2000, complete
the following steps:
Step 1
Step 2
Step 3
The other side of the grounding cable must be connected to the site equivalent of the AC earth.
Figure 4-10: Grounding the Unit (AC)
SCE 2000 4xGBE Installation and Configuration Guide
4-14
From the enclosed Grounding kit, remove the necessary materials: the grounding cable
(green and yellow colored cable) and pairs of hex nuts and spring washers.
On the Rear panel of the SCE 2000, locate the chassis grounding connector (refer to the
appropriate figure for an AC- or DC-powered SCE 2000 below).
Attach the grounding cable (green and yellow colored cable), firmly fastening the
(enclosed) hex nuts and spring washers with a #¼" hex wrench (refer to the appropriate
figure for an AC- or DC-powered SCE 2000 below).