Cisco CE 2000 Platform SCE 2000 4xGBE Installation And Configuration Manual page 69

Cisco systems ce 2000 platform installation and configuration guide
Hide thumbs Also See for CE 2000 Platform SCE 2000 4xGBE:
Table of Contents

Advertisement

Chapter 5
Connecting the Management Interfaces and Performing Initial System Configuration
SNMP agent status
GET community names
SET community names
trap managers (maximum
20)
Authentication Failure
trap status
enterprise traps status
system administrator
Topology Configuration
connection mode
type of deployment
physically connected link
(cascade topology only)
priority
(cascade topology only)
on-failure behavior
(inline connection mode
only)
Admin status of the SCE
2000 after abnormal boot
Following are some general instructions regarding the setup dialog:
All default values appear in square brackets [default].
If no value appears in the brackets [], or more than one option appears [yes/no], then this
parameter does not have a default value.
To accept the default value, press Enter.
If you need more information about any parameter, type ? and press Enter.
A help message will appear describing the expected format of the parameter and any other
requirements.
To jump to the end of the setup dialog at any point, accepting all remaining default values,
press ^z.
OL-7824-02
Enable or disable SNMP management.
Community strings to allow GET access and associated ACLs (maximum
20).
Community strings to allow SET access and associated ACLs (maximum
20).
Trap manager IP address, community string, and SNMP version.
Sets the status of the Authentication Failure traps.
Sets the status of the enterprise traps.
Name of the system administrator.
Is the SCE 2000 installed in bump-in-the-wire topology (inline) or out of
line using an optical splitter (receive-only)?
Is this a cascade topology, with two SCE 2000s connected via the cascade
ports? Or is this a single platform topology?
In a cascade deployment this parameter sets the index for the link that this
SCE 2000 is deployed on. The options for SCE 2000 are link-0 or link-1.
In a single-SCE 2000 Platform deployment this parameter is not relevant
since one SCE 2000 is deployed on both links. In this case the link
connected to port1-port2 is by default link-0 and the link connected to
port3-port4 is by default link-1.
If this is a cascaded topology, is this SCE 2000 the primary or secondary
SCE 2000?
If this SCE 2000 is deployed inline, should the failure behavior be bypass
or cutoff of the link?
After a reboot due to a failure, should the SCE 2000 remain in a Failure
status or move to operational status provided no other problem was
detected?
SCE 2000 4xGBE Installation and Configuration Guide
Initial System Configuration
5-5