Chapter 4
Installation and Maintenance
Note
For AC-input power, we recommend powering the SCE 2000 platform from a 120 VAC, 15A receptacle
U.S. (240 VAC, 10A international) at the power source.
15 A branch circuit protection is recommended.
Step 2
Step 3
Step 4
Step 5
This completes the steps for reconnecting the AC-input power supply to the SCE 2000 platform.

Reconnecting DC-Input Power Supply Unit

The following procedures explain how to reconnect a DC-input power to the SCE 2000 platform.
Warning
Before completing any of the following steps, and to prevent short-circuit or shock hazards, ensure that
power is removed from the DC circuit. To ensure that all power to the power supply unit is OFF, locate
the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF
position, and tape the switch handle of the circuit breaker in the OFF position.
Note that the power to the relevant power supply unit should be off, not necessarily all power to the
SCE 2000 platform. One DC-input power supply can be running when the other power supply is being
removed or replaced.
Wiring should be done by a professional in accordance with state and local electrical codes.
Warning
To reconnect the DC-input power to the SCE 2000 platform, complete the following steps:
Step 1
Step 2
OL-7824-02
Plug the AC power supply cable into the AC power source.
Turn the on/off switch to the on (⏐) position.
Look at the IN and OK LEDs on the power supply unit and the corresponding Power
LED on the front panel. If the new AC-input power supply unit is operating properly,
these LEDs will be glowing green.
Ensure that the power supply is properly aligned and the installation screw is tightened.
Ensure that the DC power line input leads are disconnected from the power source.
Using the number 2 Phillips screwdriver, remove the protective plate from the terminal
block.