Fan Module Overview; Removing And Replacing The Fan Module - Cisco CE 2000 Platform SCE 2000 4xGBE Installation And Configuration Manual

Cisco systems ce 2000 platform installation and configuration guide
Hide thumbs Also See for CE 2000 Platform SCE 2000 4xGBE:
Table of Contents

Advertisement

Chapter 4
Installation and Maintenance
This completes the steps for reconnecting the DC-input power supply to the SCE 2000 platform.

Fan Module Overview

The fan module provides cooling for the internal components. The fan drawer is a field-
replaceable unit containing five fans, and is installed at the right rear of the SCE 2000 platform.
When a fan malfunctions, the fan module should be replaced as promptly as possible. Although it
is possible for the unit to function for some time with one non-functioning fan, this is not optimal
or recommended.
Figure 4-16: SE2000 Fan Module
When a fan failure occurs, the environment monitor will send an error message to the console. An
SNMP trap indicating that the fan is not functioning properly is also sent. Note that a fan failure is
often audible.

Removing and Replacing the Fan Module

The following sections explain how to remove and replace a fan module in a SCE 2000 platform:
OL-7824-02
Removing the Fan Module (on page 4-26)
Replacing the Fan Module (on page 4-26)
SCE 2000 4xGBE Installation and Configuration Guide

Fan Module Overview

4-25