Installing the SCE 2000 Platform

Site Requirements

The following tables contain the site requirement specifications for the SCE 2000.
Table 4-2
Specification
Temperature -
Short term temperatures*
Relative humidity
Heat dissipation
*Short term is defined as not more than 96 consecutive hours, not more than 15 days in one year.
360 hours total in any given year, but no more than 15 occurrences in a one-year period.
Table 4-3
Approval
EMC
Safety
For more complete information regarding safety and regulatory compliance, refer to the
Regulatory Compliance and Safety Information for the Cisco Service Control Engine document.
The DC-powered SCE 2000 should be installed in a Restricted Access Location only.
Warning

Installing the SCE 2000 Platform

The SCE 2000 operates as either a tabletop or a rack-mounted unit. A rack-mounting kit is
included with the SCE 2000 when it is shipped from the factory. The kit provides the hardware
needed (see SCE 2000 Components List) to mount the SCE 2000 in either of two types of
standard 19-inch equipment rack:
SCE 2000 4xGBE Installation and Configuration Guide
4-4
SCE 2000 Environmental Requirements
SCE 2000 Approvals Specifications
Specification
• CE Mark
• EMISSIONS: FCC Part 15 CFR 47 Class A, EN 55022 Class A, CISPR22
Class A, VCCI Class A, AS/NZS CISPR22 Class A
• Immunity - EN 50082-1 EN 55024, CISPR24 (ESD, RFI, EFT, etc.)
(Commercial)
UL/CSA 60950, IEC60950, EN60950, AS/NZS, 60950, NOM-
019,IEC/EN60825-1, -2, 21CFR1040, 73/23/ECC
19-inch rack with only two posts in the front: Use the supporting brackets included in the kit
19-inch rack with four posts, two in the front and two in the back: Use the crossrail supports
included in the kit
Acceptable Range
nominal 41°F to 104°F (5°C to 40°C)
23°F to 131°F (-5°C to +55°C)
5% to 95% (non-condensing)
683 BTU/hour
Chapter 4
Installation and Maintenance
OL-7824-02