Front Panel
Table 2-2
Port
Mng1/
Mng2
Console
AUX
GBE ports 1-
4
Table 2-3
LED Groups
Power A
Power B
Status
SCE 2000 4xGBE Installation and Configuration Guide
2-4
SCE 2000 Ports
Quantity
Description
2
10/100/1000 Ethernet RJ-45 ports for
management of the SCE 2000.
Mng 2 is currently not operational.
CLI designation: 0/0.
1
RS-232 RJ-45 port for use by
technicians
1
RS-232 RJ-45 port used by technicians
4
GigabitEthernet SC ports for connecting
to the line and/or cascading two devices
CLI designation: 0/1 through 0/4
SCE 2000 LED Groups
Description
• Continuous green: Power supply A is functioning normally
• Red: Power supply A present, but malfunctioning
• Unlit: Power supply A is either not present or has failed.
• Continuous green: Power supply B is functioning normally
• Red: Power supply B present, but malfunctioning
• Unlit: Power supply B is either not present or has failed.
The Status LED indicates the operational status of the SCE 2000 system, as
follows:
• Unlit: indicates no power from either power unit.
• Orange: indicates that the system is booting up.
• Flashing green: indicates that the system is fully operational.
• Flashing orange: indicates that the system is operational, but is in a warning
state.
• Red: indicates that there is a problem or failure
Note that Alarms are hierarchical: Failure takes precedence over Warning, which
takes precedence over operational.
Chapter 2
Overview of the SCE 2000 Platform
Connect This Port To...
A LAN using an FE cable
with an RJ-45 connector
A local terminal (console)
using an RS-232 cable with
an RJ-45 connector, as
provided in the SCE 2000
kit.
Refer to Connecting the Line
Ports (Connecting the Line
Ports
"Connecting the line
ports to the
network" on
page 6-1) for cabling
diagrams for various
topologies
OL-7824-02