Advertisement

Possible Cause
retro-reflective
target (photocell)
Cable damaged
Damaged connector
and/or bent pin
Problem: Unit Not Printing
Damaged connector
and/or bent pin
Bad cable
Printer setup/charge
Problem: Strobex Not Flashing
Power not attached
No incoming RPM
Damaged connector
and/or bent pin
Bad cable
Possible Strobex
failure
6.4.2.2
If the user has extreme difficulty in acquiring a vibration
reading, do one or more of the following actions:
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
Corrective Action
Use the correct target width.
Inspect the cable for damage, short circuits,
bent pins, and/or opens.
Inspect the nine-pin connector for damage.
Inspect the nine-pin connector for damage.
Inspect the cable. Replace it if necessary.
Ensure that the printer is correctly set up and
powered.
Check the general Strobex setup. Ensure that
the external power is attached and on.
The Strobex flashes once when the user pulls
its trigger. Check the incoming RPM
transducers and the general setup.
Inspect the nine-pin connector for damage.
Inspect the cable. Replace it if necessary.
Refer to the Strobex Operation and
Maintenance Manual for additional
troubleshooting.
No Vibration Reading