Chapter 5 – General Operation
12. Press the
screen similar will appear:
NOTE: Because many acquisitions may be used to acquire
track data, the user must explicitly save the desired runs if
they are to be later printed or reviewed.
13. If the tracker fails to acquire data, an error screen will
appear. The errors and their possible are as follows:
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
The QUAL:xx-yy indicator is a rough indicator of
track data quality where yy indicates the total amount of
rotations gathered. The xx indicates the amount of
"good" rotations used in the final displayed average. The
main reason "bad" rotations are discarded is because of
too many or too few track pulses in the blade track
window for a particular blade.
key to obtain a track solution. A solution
START
= = = = T R A C K S O L U T I O N = = =
( f l a t s )
1 :
0 . 0 0 2 : - 3 . 0 0
3 :
3 . 0 0 4 :
► S A V E R U N
N e x t r u n , p u s h S T A R T
Like the measurements the solution adjustments are
displayed in passing order.
Use the
SAVE RUN
NO RPM-Check Mag PU A: Check cables and
connections from magnetic pickup to MAG PU CH A of
the EV2K+. Check the pick-up gap.
No Track Pulses-Check Mag PU B: Check
cables and connections from FasTrak
0 . 0 0
1 o f 1 0
context key to save the current run.
13841 Rev A
140
®
to MAG PU CH