4. Install FasTrak
Guide for that model.
5. Connect FasTrak
cable to the channel B connector of the Vibrex unit.
6. Follow instructions in paragraph 5.5.1.3 to select tracker
configuration and enter the track menu.
7. Press the
appear. The user should verify the tracker settings match the
given helicopter model.
8. Use the
rotations used to average the track readings (the default is
HIGH).
9. Press the
appear as shown below. The user should verify that the RPM
is stable and TRK DATA is relatively stable.
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
®
and mounting bracket as per Application
®
cable from FasTrak
key. The following menu shown below
FasTrak
R o t o r D i a m e t e r
7 8 2 8 m m
T r a c k e r S e n s i t i v i t y
1 9 8 8 2 m m / R E V
A d j m n t S e n s i t i v i t y
6 . 5 0 f l a t s / I N
► A v e r a g i n g < H I G H >
i f o k , p u s h S T A R T
key to select the amount of rotor
Averaging
HIGH averaging: 40 rotor rotations.
MEDIUN averaging: 24 rotor rotations.
LOW averaging: 16 rotor rotations. Low averaging
returns a faster result and can be used to repeatedly
acquire data to access the variability of the track data.
key. An input verification screen will
START
Chapter 5 – General Operation
®
13841 Rev A
137
to magnetic pickup

Advertisement