5.5.1.4
The Enhanced Vibrex 2000 Plus allows track configurations to be
saved for later use. These may be saved to "tweak" the factory
settings to more closely match observed Strobex readings, to
create new track regimes and change types or even to create
configurations for new helicopter models.
1. From the main Track menu, press the
CONFIG
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
B of the EV2K+. Ensure that the FasTrak
power.
Missing Track Data-Check
sun/blades/log: Not all blade windows have valid
data. Check angle of sun into tracker lens – sun should
not come directly into lens. Move helicopter if possible.
Check condition of paint on the blades where tracker
lens is pointing. Shiny or glinting leading edges should
be covered with black paint or sight black. Check
EV2K+ battery voltage using the STATUS menu.
Replace low batteries. If these fail, use the print function
as described in paragraph 3.3.4.1 to print the OBT
DEBUG log and contact equipment representative.
Bad Track Data-Check sun/blades/log:
This is similar to missing track data above but no
windows are getting valid data, It is an indication that
the tracker is getting extra or missing pulses in the blade
windows. Also check that the proper aircraft
model/number of blades is selected.
No Data-Check Mag PUs A & B: Check both
mag inputs as above.
Saving or Removing User Track
Configurations (EV2K+ Only)
key. A series of three menus will allow the
Chapter 5 – General Operation
CHANGE TRACK
13841 Rev A
141
®