Honeywell POSI3 USB Quick Start Manual
Hide thumbs Also See for POSI3 USB:

Advertisement

Quick Links

Quick Start Guide Overview
This Quick Start Guide is designed to help you install
your Posi3 USB with basic options that apply to most
users for first time use using a Windows 32/64bit PC
(Windows XP to Windows 7 operating system). For
advanced installations please refer to either the included
Setup Guide or the help file by pressing F1 at any time
during installation.
Table of Contents
Posi3 USB Components
Software Installation
Database Set Up
Hardware Set Up
User Set Up
Adding SBCA Models
Testing
Posi3 USB Components
Unpack the Posi3 USB and accessories and verify that
all parts are present. Do not discard the shipping
cartons and packing materials – they are necessary for
returning the Posi3 USB to Honeywell Analytics for its
annual calibration.
Posi3 USB
Head Assembly
Tygon
tube
Low Pressure Manifold*
High Pressure Manifold*
First Stage Manifold*
Head Gasket
POSI3 USB Quick Start Guide
1
Page
4 Standoffs
4 Tightening Knobs
CD-ROM
Setup Guide
Quick Start Guide
USB Cable
Power Cable
3 High Pressure Manifold Replacement O-Rings*
3 Low Pressure Manifold Replacement O-Rings*
High Pressure Manifold Replacement Hex-Head
Screw*
Spare Fuse (2)
*Not included with European model.
Basic Software Installation
All POSI3 USB software end users must have
permission to modify the following areas of the PC:
1. The registry section
HKEY_LOCAL_MACHINE\SOFTWARE\Sperian\Pos
i3 USB and all its subsections.
2. The folder location C:\Program
Files\Sperian\Posi3USB and all its subfolders.
It may be necessary to contact your IT department so
they can provide you with the necessary access.
Note on Brand-Specific Software: If you are planning to service a
specific brand of SCBA, make sure you have the OEM Posi3 USB
software for that brand.
1. To install your POSI3 USB software, if having a
CD, insert the CD-ROM. If the software fails to
launch automatically, use Windows Explorer to
navigate to the CD-ROM drive and run
BATestSetup.exe. If having a downloaded file, be
sure to have the BATestSetup.exe and the
License.exe applications in the same folder.
2. It is recommended to exit any other Windows
programs that may be running and verify the
License information and End User License
Agreement.
of 11
P/N 13-395 11/4/20 Rev.05

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell POSI3 USB

  • Page 1 Note on Brand-Specific Software: If you are planning to service a specific brand of SCBA, make sure you have the OEM Posi3 USB software for that brand. 1. To install your POSI3 USB software, if having a CD, insert the CD-ROM.
  • Page 2: Database Setup

    POSI3 USB Quick Start Guide 3. By default, the software is installed to C:\Program Files (x86)\Sperian\Posi3USB\Standard\BATest. 4. Follow the screen prompts to continue installation 3. The PostgreSQL installation will begin with default settings. automatically. Database Setup The Database Installation Wizard is automatically launched near the end of the software installation.
  • Page 3 Note on Brand-Specific Software: If you are planning to service a specific brand of SCBA, make sure you have the OEM Posi3 USB software for that brand. 1. To install your POSI3 USB software, if having a CD, insert the CD-ROM.
  • Page 4 POSI3 USB Quick Start Guide 2. Choose the Advanced Installation and click "Install" 5. Select the Install directory. By default, C:\Program Files\PostgreSQL\10. Click Next. 6. Select all components to be installed 3. The PostgreSQL installation will begin automatically. A separate application is used to install the server. F1 help is not available in the database installation application.
  • Page 5 POSI3 USB Quick Start Guide 8. Assign a User and Password for the 10. For Advanced Options, select the [Default PostgreSQL Server. By recommendation use locale] configuration. Click Next. a. User: postgres b. Password: postgres Click Next. 11. Review the Installation Summary and if all configurations are correct click Next.
  • Page 6 POSI3 USB Quick Start Guide 12. Installation will require a confirmation then will proceed without interference 16. When you are back at the Database Installation Wizard, click Next to install the model’s database. 13. When the installation is done, uncheck Launch Stack Builder at exit.
  • Page 7: Install The Microphone (Optional)

    Do not mount an SCBA facepiece on the test head prior to turning the Posi3 USB on. Install the USB Drivers A "Found New Hardware" wizard is shown the first time you connect the Posi3 USB to the PC and turn it on. P/N 13-395 11/4/20 Rev.05 Page of 11...
  • Page 8: Launch The Software

    Windows Update to search for software, select No. Launch the Software The Posi3 USB should be connected to the PC and turned on prior to launching the software the first time. Double-click the desktop icon or click the Start button / All...
  • Page 9 Adding SCBA Models Note: This step is only necessary in Standard Version Posi3 USB software. Brand-specific versions of software come with pre-installed models and do not allow end users to configure models.
  • Page 10 POSI3 USB Quick Start Guide Note: "MP" stands for Medium Pressure. For models with a Medium Pressure connection in the Standard Software, the medium pressure readings will be shown on appropriate tests. The Standard Software does not contain tolerances for the medium pressure tests, so there will be no indication whether the medium pressure portion of the tests passes or fails.
  • Page 11 4500 PSI SCBA. 4. Connect the handwheel on the single end of the manifold to the Posi3 USB through the high pressure inlet fitting on the lower right front panel of the Posi3 USB. Make sure it is tight.