Honeywell Vibrex 2000 User Manual page 121

Digital dynamic balancer / analyzer systems
Table of Contents

Advertisement

?
SENSITIVITY SETUP
► [ 35.00] GMS/IPS
► [12:00] CLOCK ANGLE
► RESTORE/RESET FIELD
General Considerations -
used in the horsepower entry field are close to those that can
balance in one or two runs. Some installations may require
different sensitivity because of the aircraft configuration (for
example, pusher propellers require less weight than would be
indicated by their horsepower).
NOTE: The Set Sensitivity feature only applies to the
propeller balance channels the user selected in the
Propeller Balance Setup screens.
Use the following values to set sensitivity:
Weight in grams per IPS
Phase correction in clock hours
If these sensitivities are known from having balanced a similar
installation in the past, the user may enter them manually for a
high probability of achieving a balance in two engine runs. The
sections that follow explain these concepts.
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
CORRECTION
if ok, push START
Chapter 5 – General Operation
For most propellers, the values
13841 Rev A
105
SELECT TO ENTER
CORRECT WEIGHT
SELECT TO ENTER
CORRECT PHASE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vibrex 2000 plusEnhanced vibrex 2000 plus

Table of Contents