Honeywell Vibrex 2000 User Manual page 190

Digital dynamic balancer / analyzer systems
Table of Contents

Advertisement

Chapter 5 – General Operation
MIN VIB: <0.0>
EV2K+ solution algorithm normally tries to solve to a
perfectly smooth solution of 0.0 IPS while still respecting
the manufacturer's adjustment limits (see
option below). Some adjustments may not have limits. For
example, Pitch Link adjustment ranges are normally
governed by reaching length limits or inspection holes. In
this case, solving to 0.0 IPS may give unreasonably large
adjustments. This option can be used to specify the lowest
target vibration. This way high vibrations can be reduced in
steps while still maintaining reasonable adjustment
magnitudes.
The available minimums are: <0.0>, <0.1>, <0.2>, <0.5>
and <1.0> IPS
ADJ PTS: [INCL ALL]
adjustments, you may find that a specific adjustment cannot
be made. For example if a weight point is maxed out. This
option allows you to exclude that point from the solution or
edit the current setting to the actual weight installed so that
solutions will still respect limits.
NOTE: If you find that the rotor or component has many
adjustments already applied, in some cases it may be easier
to return the component to nominal conditions, retake the
balance measurement and try a fresh solution.
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
context key (Minimum vibrations). The
context key. Upon trying to make
13841 Rev A
174
RESPECT LIM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vibrex 2000 plusEnhanced vibrex 2000 plus

Table of Contents