Chapter 5 – General Operation
configuration to be saved under the same name, a new name
or removed. To save changes all three menus must be
followed to SAVE CONFIG AS menu. See below:
2. Use TRACK CONFIG menus 2 and 3 to edit the parameters
as desired.
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
?
T R A C K C O N F I G 1 o f 3
A - 1 0 9 E G n d F a c t o r y
► R E M O V E C O N F I G
► A D D F A C T O R Y C O N F I G
► < 4 > R o t o r B l a d e s
t o 2 o f 3 , p u s h S T A R T
Press the
REMOVE CONFIG
selected user configuration. Note that factory default
configurations cannot be removed.
Press the
ADD FACTORY CONFIG
configuration. This is done exactly the same as when the
TRACK menu is first entered as per paragraph 5.5.1.2.
Up to ten user configurations may be added.
: Selects the number of main rotor blades.
Rotor Blades
ROTOR DIAMETER
mm). This parameter only affects the lead-lag
measurements. Increasing the diameter linearly increases
the computed lead-lag.
TRACKER SENSITIVITY
(in mm/REV). This parameter affects the blade track
height. The factory number is derived from calculations
based on rotor geometry and FasTrak
position and is calibrated to observed Strobex readings.
key to remove the currently
: Change the main rotor diameter (in
: Change the tracker sensitivity
13841 Rev A