3. Use the following screen to select the measurement name
A - 1 0 9 E P o w e r
► M E A S : < M / R L >
► B A L C H A N : < 1 A >
► A u t o C o r r e c t i o n < O F F >
and the Vibrex channel number:
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
A - 1 0 9 E P o w e r
C o m p o n e n t :
► < M R S i d e T r k r >
R e g i m e :
► < 1 0 0 % G r o u n d
C h a n g e T y p e :
► < P i t c h L i n k >
i f o k , p u s h S T A R T
Select
Component.
Select
.
Regime
Select
Change Type
NOTE: The above three context keys are "interactive"
with each other with top most buttons having priority,
i.e. if a new component is selected, the Regime and
Change Type context below will be changed to match
the balance charts in the selected component.
Press the
START
regime and change type are selected.
i f o k , p u s h S T A R T
Chapter 5 – General Operation
R u n 1
.
key when the proper component,
R u n 1
13841 Rev A
165
>