Parameter
MEASURED_PRODUCT
LOWER_PRODUCT_DC
UPPER_PRODUCT_DC
VAPOR_DC
SENSOR_HEIGHT
MAX_PRODUCT_HEIGHT
Rev.5
Measured product Type
1. Single Liquid
2. Two Liquid Non Flooded
3. Two Liquid Flooded
Single Liquid
Dielectric constant value of Lower Product to be measured if two
products exist in the tank
Dielectric constant of upper product to be measured. For single
liquid this is Product DC.
Dielectric constant of the vapor.
The height from the reference point at which sensor is mounted
A represents Sensor Height
Maximum Product Height can be equal to or less than the Sensor
Height. It is the valid height till which the liquid raised can be
measured.
B represents Max Product Height/ Max Product Level
FOUNDATION Fieldbus Option User's Manual
Description
2 Liquid Flooded
2 Liquid Non Flooded