Parameter
INTERFACE_LEVEL
INTERFACE_DISTANCE
INTERFACE_LEVEL_RATE
VAPOR THICKNESS
PRODUCT_VOLUME
PRODUCT_VOLUME_RANGE
ELECTRONIC TEMPERATURE
VAPOR_VOLUME
UPPER_PRODUCT_VOLUME
LOWER_PRODUCT_VOLUME
UPPER_PRODUCT_THICKNES
S
TRANSMITTER_MODEL
(read only)
SENSOR_CONNECTION
(read only)
Page 28
FOUNDATION Fieldbus Option User's Manual
Displays interface level. The Range and unit selected for Product
Level will automatically get reflected for Interface Level.
The distance of the interface level from the sensor.
The rate of change of the interface level.The Range and unit
selected for Product Level rate will automatically get reflected for
Interface Level rate.
The height of the vapor/air inside the tank.
The volume of the product is calculated according to the volume
calculation type selected by the RLAUXTB (Transducer Block).
The volume calculation may be as per the Ideal Tank Shape or
Strapping Table. Refer Table 8 for more details on Volume
calculations.
The product volume range is the range from 0 to the maximum
tank volume size considering maximum product height as the tank
height. It also contains unit for product volume. The supported
units are:
L
ft3
in3
gallon
ImpGal
bbl
bbl liquid
yd3
m3
The electronic temperature of the communication board. It also
contains the unit for temperature. The supported units are:
°C
°F
The volume of the vapor / air inside the tank.
The upper liquid volume which is obtained by subtracting the lower
liquid volume from the product volume.
The lower liquid volume calculated using the interface level
The height of the upper liquid when two liquids option is selected in
Measured Product.
SLG720: Standard
SLG726: High Temperature and High Pressure
Direct
Remote
Description
Rev.5