Message
Type
ECT Timeout #
Set
ECT Timeout #
Clear
Memory Usage
Set
Host
Memory Usage
Clear
Host
Memory Usage
Set
Secondary
Memory Usage
Clear
Secondary
FPGA Code
Set
Version
FPGA Code
Clear
Version
Message
Cause/Remedy
ECT # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
ECT fault cleared –
Excessive
Cause: Possible software
(stack/partition)
issue.
memory usage
Remedy: Clear
warnings, reset the unit,
and notify Cisco
Services if the problem
persists.
Normal
(stack/partition)
memory usage
Excessive
Cause: Possible software
(stack/partition)
issue.
memory usage
Remedy: Clear
warnings, reset the unit,
and notify Cisco
Services if the problem
persists.
Normal
(stack/partition)
memory usage
FPGA newer
Cause: FPGA version is
than SW,
incompatible with the
Supported=AAA,
software.
Running=BBB
Remedy: Select alternate
FPGA, software
versions, reset unit,
notify Cisco Services if
the problem persists.
FPGA code ver
OK
Description
No longer receiving
Event Control Table.
SW exceeding
allowable memory
usage.
Software exceeding
allowable memory
usage.
FPGA version is
incompatible with
currently operating
software. You may
encounter operational
difficulties
ID
77200
77200
78000
78000
79000
79000
80000
80000