Chapter 6 Service and Maintenance
Alarm
Message
Type
PE n: Loss of
Clear
Input
Digital
Set
Program
Mapping
Digital
Set
Program
Mapping
Digital
Set
Program
Mapping
296
Message
Cause/Remedy
Fault reset
–
PID Collision
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink
to find the
appropriate
system settings.
Program Collision
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink
to find the
appropriate
system settings.
Mode-i PMT out
Cause: Uplink
settings may have
of range
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink
to find the
appropriate
system settings.
Description
Severity
–
Minor
Two source
Minor
service PIDs
are being
mapped to the
same output
PID. This will
cause data
corruption in
the stream.
Two source
Minor
channel
numbers are
being mapped/
passed to the
same channel
number in the
output.
PMT PID to be
Major
used for Mode-
i is outside of
valid MPEG
PID range.
ID
11000
12000
13000
14000
15000
16000
17000
18000
18009-18032
19000
19000
19000