Cisco D9824 Installation And Configuration Manual page 349

Advanced multi decryption receiver
Table of Contents

Advertisement

Warning
Message
Type
CI Status
Set
CI Status
Clear
Video Format
Set
Mismatch
Video Format
Clear
Mismatch
Temperature
Set
Warning
Temperature
Clear
Warning
FPGA
Set
Temperature
Warning
FPGA
Clear
Temperature
Warning
VBI Data
Set
Message
Cause/Remedy
Different CA
Cause: Different CA
Systems in
systems are used in the
Top/Bottom
slots.
Slots
Remedy: Replace the CA
cards to use the same
CA system.
OK
Video format
mismatch
Video format
match
Temperature
Cause: Room
over Warning
temperature too high, or
threshold
air flow is blocked.
Remedy: Check
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.
Temperature
normal
Temperature
Cause: Room
over Warning
temperature is too high,
threshold
or air flow is blocked.
Remedy: Check the
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.
Temperature
normal
2nd VBI PID
Cause: Uplink
attempt to write
configuration issue.
same line
Remedy: Contact uplink
to verify expected VBI
settings.
Description
Different CA Systems
in Top/Bottom slots.
Video Format
Mismatch.
Temperature is above
normal operating
range.
Temperature is within
the normal operating
range.
FPGA temperature is
above normal
operating range.
FPGA temperature is
within the normal
operating range.
Conflicting VBI data
on second VBI PID.
ID
42500
42500
43000
43000
44000
44000
45000
45000
49000
327

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents