Cisco D9824 Installation And Configuration Manual page 343

Advanced multi decryption receiver
Table of Contents

Advertisement

Alarm
Message
Type
FEC FPGA
Set
Status
FEC FPGA
Set
Status
FEC FPGA
Set
Status
FEC FPGA
Clear
Status
Message
Cause/Remedy
FEC FPGA failed
Cause: Hardware
to start
issue.
Remedy: Ensure
that the USB Flash
is installed,
formatted, and the
image is loaded.
Also, ensure that
the FEC FPGA is
installed and the
CPLD is properly
programmed.
FEC FPGA access
Cause: Hardware
failed
issue.
Remedy: Ensure
that the USB Flash
is installed,
formatted, and the
image is loaded.
Also, ensure that
the FEC FPGA is
installed and the
CPLD is properly
programmed.
FEC FPGA
Cause: Hardware
initialization failed
issue.
Remedy: Ensure
that the USB Flash
is installed,
formatted, and the
image is loaded.
Also, ensure that
the FEC FPGA is
installed and the
CPLD is properly
programmed.
FEC FPGA is
running OK
Description
Severity
FEC FPGA is
Major
loaded, but
failed to start
(not ready).
FEC FPGA is
Major
loaded and
started, but
attempt to read
configuration
registers failed.
FEC FPGA is
Major
loaded and
started, but
initial
parameter
setup failed.
FEC FPGA is
Major
loaded, started,
initialized, and
is fully
operational.
ID
92400
92400
92400
92400
321