5. PARAMETERS
Class No. Symbol
2
www.DataSheet4U.com
3
CMX
4
ATU
Auto tuning
Used to selection the response level, etc. for execution of auto tuning.
Refer to Chapter 7.
0
0
Auto tuning response level setting
Set
value
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
If the machine hunts or generates
large gear sound, decrease the
set value.
To improve performance, e.g.
shorten the settling time, increase
the set value.
Gain adjustment mode selection
(For more information, refer to Section 7.1.1.)
Set
Gain adjustment mode
value
Interpolation mode
0
Auto tuning mode 1
1
2
Auto tuning mode 2
3
Manual mode 1
Manual mode 2
4
Electronic gear numerator
Used to set the electronic gear numerator value.
For the setting, refer to Section 5.2.1.
Setting "0" automatically sets the resolution of the servo motor
connected.
CDV
Electronic gear denominator
Used to set the electronic gear denominator value.
For the setting, refer to Section 5.2.1.
Name and function
Response
Machine resonance
level
frequency guideline
Low
15Hz
response
20Hz
25Hz
30Hz
35Hz
45Hz
55Hz
Middle
70Hz
response
85Hz
105Hz
130Hz
160Hz
200Hz
High
240Hz
response
300Hz
Description
Fixes position control gain 1
(parameter No. 6).
Ordinary auto tuning.
Fixes the load inertia moment
ratio set in parameter No. 34.
Response level setting can be
changed.
Simple manual adjustment.
Manual adjustment of all gains.
5 - 6
Initial
Setting
Control
Unit
value
range
mode
0105
P S
Refer to
Name
and
function
column.
1
0
P
1
to
65535
1
1
P
to
65535

Hide quick links: