2. INSTALLATION
2.2 Installation direction and clearances
CAUTION
(1) Installation of one servo amplifier
www.DataSheet4U.com
10mm
(0.4 in.)
or more
(2) Installation of two or more servo amplifiers
Leave a large clearance between the top of the servo amplifier and the internal surface of the control
box, and install a fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.
The equipment must be installed in the specified direction. Otherwise, a fault may
occur.
Leave specified clearances between the servo amplifier and control box inside
walls or other equipment.
Control box
40mm
(1.6 in.)
or more
Servo
amplifier
MODE
SET
10mm
CN3
(0.4 in.)
MITSUBISHI
MR-
or more
CN1
CN2
CNP2
CNP1
40mm
(1.6 in.)
or more
30mm
(1.2 in.)
or more
Control box
Wiring clearance
70mm
(2.8 in.)
Control box
100mm
10mm
(4.0 in.)
(0.4 in.)
or more
or more
MODE
SET
MODE
SET
CN3
CN3
MITSUBISHI
MITSUBISHI
MR-
MR-
CN1
CN1
CN2
CN2
CNP2
CNP2
CNP1
CNP1
40mm
(1.6 in.)
or more
2 - 2
Top
Bottom
30mm
(1.2 in.)
or more