Mitsubishi Electric MR-E A Series Instruction Manual page 227

General-purpose ac servo
Hide thumbs Also See for MR-E A Series:
Table of Contents

Advertisement

14. SERVO MOTOR
Item
Applicable servo
amplifier/drive unit
(Note 1,11)
Continuous
duty
(Note 1) Rated speed
Maximum speed
Permissible instantaneous speed
Maximum torque
www.DataSheet4U.com
Power rate at continuous rated torque
(Note 3)
Inertia moment
(Note 2) Recommended ratio of load inertia
moment to servo motor shaft inertia moment
(Note4)
Regenerati
ve brake
duty
MR-E
[times/min]
series
Power supply capacity
Rated current
Maximum current
Speed/position detector
Accessories
Insulation class
Structure
(Note 7) Environmental conditions
(Note 3) Weight
Note: 1. When the power supply voltage drops, we cannot guarantee the output and rated speed.
2. If the load inertia moment ratio exceeds the indicated value, please consult us.
3. When the servo motor is equipped with electromagnetic brake, refer to section 14.8.When the servo motor is equipped with
reduction gear, please consult us.
4. The regenerative brake duty indicated is the permissible duty when the servo motor running without load at the rated speed is
decelerated to a stop. When a load is connected, the value in the table is multiplied by 1/(m
moment/motor inertia moment. At the speed higher than the rated, the permissible number of times is in inverse proportion to
the square of (running speed/rated speed). When the running speed varies frequently or when the regenerative mode
continues as in vertical feed, calculate regenerative heat generated during operation. Provisions must be made to keep this
generated heat below the permissible value.
5. If the effective torque is within the rated torque range, there are no restrictions on the regenerative duty. Note that the
recommended load inertia moment ratio is 15 times or less.
6. Except for the shaft-through portion and connector end.
7. When the equipment is to be used in places where it is subjected to oil and/or water, such as on machine field sites, optional
features apply to the equipment. Please contact.
8. When the servo motor is provided with the reduction gear, the protection type of the reduction gear section is IP44.
9. At the load inertia moment ratio of 5 times or less, there are no restrictions on the regenerative duty if the effective torque is
within the rated torque range.
10. The regenerative brake duty of the 400W or less servo amplifier may vary under the influence of the power supply voltage
because of the large ratio of the energy for charging the electrolytic capacitor in the servo amplifier.
Servo Motor
MR-E- A
Rated output
[kW]
[N m]
2.39
Rated
torque
[oz in]
[r/min]
[r/min]
[r/min]
[N m]
7.16
[oz in]
1015
[kW/s]
4
J
[ 10
kg m
]
2
WK
[oz in
]
36.1
2
2
Servo amplifier' built-
in regenerative brake
resistor
MR-RB032(30W)
MR-RB12(100W)
MR-RB32(300W)
MR-RB30(300W)
MR-RB50(500W)
Refer to "Power supply equipment capacity and generated loss of servo amplifiers"
in Servo Amplifier Instruction Manual.
[A]
[A]
[kg]
[lb]
11.0
HC-SFE Series
(Middle inertia, middle capacity)
52
102
70
100
0.5
1.0
4.78
339
677
3000
345
14.4
2041
8.7
16.7
6.6
13.7
74.9
15 times or less
56
54
165
80
560
270
810
3.2
6
9.6
18
Encoder
(resolution: 10000 pulse/rev)
Encoder Oil seal
Class F
Totally-enclosed, self-cooled
(protection type: IP65(Note 8))
Refer to section 2.1
5.0
7.0
15.4
14 - 20
152
200
1.5
7.16
1015
2000
21.6
3061
25.6
20.0
109
136
408
680
9
27
9.0
19.8
1), where m
load inertia
202
200
2.0
9.55
1353
2500
2850
28.5
4039
21.5
4.5
232
64
192
320
11
33
12.0
26.5