Mitsubishi Electric MR-E A Series Instruction Manual page 291

General-purpose ac servo
Hide thumbs Also See for MR-E A Series:
Table of Contents

Advertisement

15. MR-E-
Class No. Symbol
49
*DO1
www.DataSheet4U.com
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Output signal selection 1
Used to select the connector pins to output the alarm code and
warning (WNG).
0
0
Setting of alarm code output
Set value
0
1
(Note) Alarm code
CN1
CN1
pin 10
pin 11
0
0
0
1
1
0
1
1
0
0
1
0
1
0
Note: 0:off
1:on
Setting of warning (WNG) output
Select the connector pin to output warning. The old signal
before selection will be unavailable.
Set value
0
1
2
3
4
Name and function
Connector pins
CN1-10
CN1-11
CN1-12
SA
RD
Alarm code is output at alarm occurrence.
Alarm
Name
CN1
display
pin 12
88888
Watchdog
AL.12
Memory error 1
AL.13
Clock error
AL.15
Memory error 2
0
AL.17
Board error 2
AL.19
Memory error 3
AL.37
Parameter error
AL.8A
Serial communication time-out error
AL.8E
Serial communication error
AL.30
Regenerative error
0
AL.33
Overvoltage
0
Undervoltage
AL.10
AL.45
Main circuit device overheat
AL.46
Servo motor overheat
0
AL.50
Overload 1
AL.51
Overload 2
AL.24
Main circuit
1
AL.32
Overcurrent
1
AL.31
Overspeed
AL.16
Encoder error 1
1
AL.1A
Motor combination error
AL.20
Encoder error 2
Connector pin No.
Not output.
CN1-11
CN1-9
CN1-10
CN1-12
15 - 46
Initial
Setting
Unit
value
0000
Refer to
Name
and
function
column.
ZP
Control
range
mode
S T