15. MR-E-
15.6.2 Alarms and warning list
When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or
warning has occurred, refer to Section 10.2.2 or 10.2.3 and take the appropriate action.
Set "
1" in parameter No. 49 to output the alarm code in ON/OFF status across the corresponding
pin and SG. Warnings (AL.E0 to AL.E9) have no alarm codes. Any alarm code is output at occurrence of
the corresponding alarm. In the normal status, the signals available before alarm code setting (CN1-12:
www.DataSheet4U.com
ZSP, CN1-11: RD, CN1-10: SA) are output.
The alarms marked
operations.
Display
AL.10
AL.12
AL.13
AL.15
AL.16
AL.17
AL.19
AL.1A
AL.20
AL.24
AL.30
AL.31
AL.32
AL.33
AL.37
AL.45
AL.46
AL.50
AL.51
AL.8A
AL.8E
88888
AL.E0
AL.E1
AL.E6
AL.E9
Note: 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. 0: off
1: on
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
POINT
Configure up a circuit which will detect the trouble (ALM) signal and turn
off the servo-on (SON) signal at occurrence of an alarm.
in the alarm deactivation column can be deactivated by the corresponding
(Note 2) Alarm code
CN1-10
CN1-11
CN1-12
pin
pin
pin
0
1
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
1
0
1
1
1
0
0
0
1
0
1
0
0
1
1
0
0
1
0
1
0
0
0
0
1
1
0
1
1
0
1
1
0
1
1
0
0
0
0
0
0
0
0
0
0
Name
Undervoltage
Memory error 1
Clock error
Memory error 2
Encoder error 1
Board error
Memory error 3
Motor combination error
Encoder error 2
Main circuit error
Regenerative error
Overspeed
Overcurrent
Overvoltage
Parameter error
Main circuit device overheat
Servo motor overheat
Overload 1
Overload 2
Serial communication time-out error
Serial communication error
Watchdog
Excessive regenerative warning
Overload warning
Servo emergency stop warning
Undervoltage warning
15 - 61
Alarm deactivation
Press
Alarm
"SET" on
Power
reset
current
OFF ON
(RES)
alarm
signal
screen.
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
Removing the cause of occurrence
deactivates the alarm
automatically.