Mitsubishi Electric MR-E A Series Instruction Manual page 293

General-purpose ac servo
Hide thumbs Also See for MR-E A Series:
Table of Contents

Advertisement

15. MR-E-
Class No. Symbol
58
www.DataSheet4U.com
59
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
NH1
Machine resonance suppression filter 1
Used to selection the machine resonance suppression filter.
(Refer to Section 8.2.)
0
Notch frequency selection
Set "00" when you have set adaptive vibration
suppression control to be "valid" or "held"
(parameter No. 60:
Setting
Frequency
value
00
Invalid
01
4500
02
2250
03
1500
04
1125
05
900
06
750
07
642.9
Notch depth selection
Setting
NH2
Machine resonance suppression filter 2
Used to set the machine resonance suppression filter.
0
Notch frequency
Same setting as in parameter No. 58
However, you need not set "00" if you have
set adaptive vibration suppression control to
be "valid" or "held".
Notch depth
Same setting as in parameter No. 58
Name and function
1
or
2
Setting
Frequency
Setting
Frequency
value
value
08
562.5
10
281.3
09
500
11
264.7
0A
450
12
250
0B
409.1
13
236.8
0C
375
14
225
0D
346.2
15
214.3
0E
321.4
16
204.5
0F
300
17
195.7
Depth
Gain
value
0
40dB
Deep
1
14dB
to
2
8dB
Shallow
3
4dB
15 - 48
Initial
Unit
value
0000
).
Setting
Frequency
value
18
187.5
19
180
1A
173.1
1B
166.7
1C
160.1
1D
155.2
1E
150
1F
145.2
0000
Setting
Control
range
mode
S T
Refer to
Name
and
function
column.
S T
Refer to
Name
and
function
column.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents