Hardware Guide
You must connect the AC power cable in compliance with local standards and
requirements.
4.6.3 DC Power Cable
4.6.3.1 DC Power Cable
Connection
A DC power cable is connected as follows:
Appearance and Structure
The DC power cables include the RTN cable, and NEG (-48 V) cable. Both the RTN
and NEG (-48 V) power cables consist of the terminal blocks and cables, as shown
in
Figure 4-186 Appearance of the DC power cable
Cable Type
NEG cable
RTN cable
Issue 08 (2022-04-20)
NO TICE
NO TE
● The cable with the C7 straight female X2 connector only to the desktop devices
USG6510E, USG6510E-POE, USG6530E.
● The cable with the C13 straight female X2 connector and non-C14 straight male X1
connector applies to non-desktop-mounted scenarios.
● The cable with the C13 straight female X2 connector and C14 straight male X1
connector applies to non-desktop models in PDU installation scenarios.
One end is connected to the matching DC power terminal on the DC power
module of the USG.
The other end is connected to an external power source.