Mitsubishi Electric MELSEC iQ-R Series User Manual page 289

Programmable controller
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

No.
Name
Description
SD1575
CC-Link module
CC-Link module
channel number
channel number
(6th module)
(6th module)
SD1576
CC-Link module
CC-Link module
channel number
channel number
(7th module)
(7th module)
SD1577
CC-Link module
CC-Link module
channel number
channel number
(8th module)
(8th module)
SD1578
CC-Link IE
CC-Link IE
Controller Network
Controller Network
module channel
module channel
number (1st
number (1st
module)
module)
SD1579
CC-Link IE
CC-Link IE
Controller Network
Controller Network
module channel
module channel
number (2nd
number (2nd
module)
module)
SD1580
CC-Link IE
CC-Link IE
Controller Network
Controller Network
module channel
module channel
number (3rd
number (3rd
module)
module)
SD1581
CC-Link IE
CC-Link IE
Controller Network
Controller Network
module channel
module channel
number (4th
number (4th
module)
module)
SD1582
CC-Link IE
CC-Link IE
Controller Network
Controller Network
module channel
module channel
number (5th
number (5th
module)
module)
SD1583
CC-Link IE
CC-Link IE
Controller Network
Controller Network
module channel
module channel
number (6th
number (6th
module)
module)
SD1584
CC-Link IE
CC-Link IE
Controller Network
Controller Network
module channel
module channel
number (7th
number (7th
module)
module)
SD1585
CC-Link IE
CC-Link IE
Controller Network
Controller Network
module channel
module channel
number (8th
number (8th
module)
module)
SD1594
Switch status
Switch status
(FUNCTION/
SHUTDOWN
switch)
SD1595
Switch status
(HARD RESET/OS
RESET switch)
*1 Only the channel number in use can be checked. A module cannot be specified.
*2 Flashing occurs at the following intervals:
 Flashing: 200 ms
 Slow flashing: 1 sec
Details
*1
Channel number (81 to 88)
of the CC-Link module (6th module)
controlled
*1
Channel number (81 to 88)
of the CC-Link module (7th module)
controlled
*1
Channel number (81 to 88)
of the CC-Link module (8th module)
controlled
*1
Channel number (151 to 158)
of the CC-Link IE Controller Network
module (1st module) controlled
*1
Channel number (151 to 158)
of the CC-Link IE Controller Network
module (2nd module) controlled
*1
Channel number (151 to 158)
of the CC-Link IE Controller Network
module (3rd module) controlled
*1
Channel number (151 to 158)
of the CC-Link IE Controller Network
module (4th module) controlled
*1
Channel number (151 to 158)
of the CC-Link IE Controller Network
module (5th module) controlled
*1
Channel number (151 to 158)
of the CC-Link IE Controller Network
module (6th module) controlled
*1
Channel number (151 to 158)
of the CC-Link IE Controller Network
module (7th module) controlled
*1
Channel number (151 to 158)
of the CC-Link IE Controller Network
module (8th module) controlled
The switch status (FUNCTION/SHUTDOWN switch) is stored as follows:
0: Neutral
1: FUNCTION
2: SHUTDOWN
The switch status (HARD RESET/OS RESET switch) is stored as follows:
0: Neutral
1: HARD RESET
2: OS RESET
Set by (when to set)
S (initial)
S (initial)
S (initial)
S (initial)
S (initial)
S (initial)
S (initial)
S (initial)
S (initial)
S (initial)
S (initial)
S (key switch change)
S (key switch change)
APPX
Appendix 5 Special Register List
A
287

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r melsecwincpu

Table of Contents