Mitsubishi Electric MELSEC iQ-R Series User Manual page 232

Programmable controller
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error name
code
185AH
USB port fault
185BH
HDMI error
185CH
Secondary CFast card
error
185DH
Already open error
185EH
Already open error
185FH
Communication error
1860H
Communication error
1861H
Communication error
1862H
Communication error
33 ERROR CODE LIST
230
33.1 Error Codes for Self-diagnostics
Error details and cause
• An overcurrent to the USB port has
been detected.
• An overcurrent to the HDMI has been
detected.
• An overcurrent to the secondary
CFast card has been detected.
• A port number that is already opened
was attempted to be opened again.
(For TCP/IP)
• A port number that is already opened
was attempted to be opened again.
(For UDP/IP)
• Generating the Listen socket failed.
• Generating the server socket failed.
• Generating the server socket failed.
• A port number that is already opened
was attempted to be opened again.
Corrective action
• Unplug the connected USB device
and check if the device has any
failure. If any, replace it.
• Click the 'Power surge on the USB
port' icon, which is displayed on the
task tray, then click the 'Reset' button
in the window appeared. If clicking the
'Close' button, the USB port stops
working until Windows is restarted.
• If the same error code is displayed
again even with a self-powered USB
hub, the possible cause is a hardware
failure of the CPU module. Please
contact your local Mitsubishi Electric
sales office or representative.
• Replace the HDMI device.
• Turn the power of the CPU module
OFF and ON or reset the hardware. If
the same error code is displayed
again, the possible cause is a
hardware failure of the CPU module.
Please contact your local Mitsubishi
Electric sales office or representative.
• Replace the secondary CFast card.
• Turn the power of the CPU module
OFF and ON or reset the hardware. If
the same error code is displayed
again, the possible cause is a
hardware failure of the CPU module.
Please contact your local Mitsubishi
Electric sales office or representative.
• Restart Windows. If the same error
code is displayed again, the possible
cause is a hardware failure of the
CPU module. Please contact your
local Mitsubishi Electric sales office or
representative.
• Restart Windows. If the same error
code is displayed again, the possible
cause is a hardware failure of the
CPU module. Please contact your
local Mitsubishi Electric sales office or
representative.
• Restart Windows. If the same error
code is displayed again, the possible
cause is a hardware failure of the
CPU module. Please contact your
local Mitsubishi Electric sales office or
representative.
• Restart Windows. If the same error
code is displayed again, the possible
cause is a hardware failure of the
CPU module. Please contact your
local Mitsubishi Electric sales office or
representative.
• Restart Windows. If the same error
code is displayed again, the possible
cause is a hardware failure of the
CPU module. Please contact your
local Mitsubishi Electric sales office or
representative.
• Restart Windows. If the same error
code is displayed again, the possible
cause is a hardware failure of the
CPU module. Please contact your
local Mitsubishi Electric sales office or
representative.
Stop/
Diagnostic
continue
timing
Continue
Always
Continue
Always
Continue
Always
Continue
Always
Continue
Always
Continue
Always
Continue
Always
Continue
Always
Continue
Always

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r melsecwincpu

Table of Contents