■Control details
Create a sequence program so that an interrupt occurs in this product when the execution command of the D(P).GINT
instruction rises (OFF  ON).
When received an interrupt from a programmable controller CPU, this product restarts a user program which is waiting for an
interrupt event with the CCPU_WaitEvent function.
■Error details
In either of the following cases, an interrupt completes abnormally, and an error code is stored in the device specified with the
completion status storage device (D2).
*1
Error code
0010H
2282H
*1 "0000H" is stored when the processing is normally completed.
In any of the following cases, an operation error occurs and the latest self-diagnostic error (SM0) turns ON. Then, an error
code is stored in the latest self-diagnostic error code (SD0).
Error code
4350
4351
4352
4353
■Program example
• Program in which the completion device and completion status are omitted
M0
• Program in which the completion device and completion status are used
M0
M100
M101
M101
12 BUS ACCESS FUNCTION
128
12.3 Interrupt Notification Reception
Description
The instruction request from the programmable controller CPU to this product exceeds the
allowable value.
The interrupt pointer number set with the D(P).GINT instruction is out of the range of 0 to 15.
Description
The specified target CPU module is wrong.
• A CPU number set as reserved has been specified.
• A CPU number of which module is not mounted has been specified.
• The start I/O number of the target CPU module divided by 16 (n1) is out of the range of 3E0H to
3E3H.
The instruction cannot be executed on the specified target CPU module.
• The instruction name is wrong.
• An instruction which is not supported by the target CPU module was specified.
The number of devices of the specified instructions is incorrect.
An unavailable device is specified in the specified instruction.
D.GINT
H3E1
K10
RST
M0
D.GINT
H3E1
K10
M100 D100
RST
Normal complete program
Abnormal complete program
Corrective action
Check and correct the
sequence program.
Corrective action
Check and correct the
sequence program.
M0