Mitsubishi Electric MELSEC iQ-R Series User Manual page 194

Programmable controller
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Operation after execution
When restarting Windows forcibly, this product operates as follows:
• The OS LED flashes, and turns ON after Windows is restarted.
• If an output (Y) is set in "Y Output Setting while Windows is Restarting," the output (Y) turns ON and then turns OFF after
Windows is restarted.
An output (Y) can be set in the following parameter:
[CPU Parameter]  [Operation Related Setting]  [Windows Setting]
Window
Displayed items
Item
Y Output Setting while Windows is
*1
Restarting
*1 To use this setting, set the Y output status to the Y OUT state by using the Y output control function. If the status is in the Y STOP or
PAUSE state, the Y output does not turn ON. (Page 197 Y OUTPUT CONTROL FUNCTION)
*2 The device set in "Y Output Setting when Windows Shut Down" cannot be set.
21 INDIVIDUAL RESET FUNCTION
192
21.2 Windows Forced Restart
Description
Set the Y device to turn ON when Windows restarted.
The device will be ON while the OS LED is flashing due to the restart
operation.
The device will not turn ON when the OS LED is flashing due to the
power-ON or shutdown operation.
Setting range
Default
*2
Y0 to FFFH
Blank

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r melsecwincpu

Table of Contents