4.
Set a module to be connected for "PLC side I/F."
5.
Double-click the icon for the set module.
The "PLC side I/F Detailed Setting" screen is displayed.
6.
Select "Connection via HUB," and enter the IP address or host name of this product.
7.
Click the [OK] button.
8.
Set "Other Station Setting" and "Network Communication Route" as necessary.
Precautions
■Connecting a target device (with the same IP address as this product) and this product by
using multiple MELSOFT connections (TCP/IP) simultaneously
Even when setting multiple MELSOFT connections (TCP/IP) in the external device configuration, some of the connections
may not be established.
To use multiple MELSOFT connections, set the following setting for the connection destination of MELSOFT products.
Condition
All the MELSOFT products to be connected simultaneously can specify an
Ethernet board adapter for their connection destination settings.
Some of the MELSOFT products to be connected simultaneously cannot
specify an Ethernet board adapter for their connection destination settings.
*1 For MELSOFT products which cannot specify an adapter, the setting will be the same as that of when "Not Specified" is specified for the
adapter setting.
Setting content
Specify the same Ethernet board adapter for the connection destination
settings.
Specify "Not Specified" for the adapter setting in the connection destination
setting of all MELSOFT products to be connected.
13 MELSOFT CONNECTION FUNCTION
*1
135
13.1 Connection Method