Connection Setting - Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual

Table of Contents

Advertisement

Model
Through
Not connected
Programmable
FR-E700-NE
controller
GOT to
programmable
*1
controller
*1
When the programmable controller is protected by a remote password, automatic recognition is disabled.
• The following shows automatic recognition condition.
PC-side port
Intermediate device
Ethernet
Not connected
USB
GOT
Ethernet
GOT
USB
GOT to
programmable
controller
USB, RS-232C,
Programmable
Ethernet
controller
(○: Enabled, ×: Disabled)
• If the network device is protected by a remote password, the "Remote password input" dialog appears during the automatic
recognition.
2.1.3

Connection setting

In the "Connection setting" of the "System setting" window, set the communication between the personal computer and
inverter, etc.
For communication with the inverter using the USB port of personal computer, set "USB" in the box of "PC-side port".
For communication with the inverter using the serial port of personal computer, set "Specify the COM port number" in the box
of "PC-side port".
For communication with the inverter using the LAN port of personal computer, set "Ethernet" in the box of "PC-side port".
NOTE
• To use the USB/RS-485 conversion cable DINV-U4, select [COM*: DTC DINV-U4 USB Serial Port (COM*)] for the PC-side
port.
• If it is not in the drop-down list although the DINV-U4 cable is connected, do the following:
Check the DINV-U4 cable for insecure connection to the personal computer.
Check if the DINV-U4 driver is already installed in the personal computer.
Pr.
Name
833
Ethernet function selection 1
834
Ethernet function selection 2
835
Ethernet function selection 3
837 to 843
Ethernet IP filter address
833
Ethernet function selection 1
834
Ethernet function selection 2
835
Ethernet function selection 3
837 to 843
Ethernet IP filter address
833
Ethernet function selection 1
834
Ethernet function selection 2
835
Ethernet function selection 3
837 to 843
Ethernet IP filter address
Automatic recognition
Direct
Hub connection
connection
×
×
Setting
Set a combination of "31" (or "32") and "20" in
any two of the parameters.
Set the IP address to within the IP address
range of the personal computer.
Set "31" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
Set "31" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
Router connection
×
2. PROJECT CREATION
2.1 Project file operation
1
2
3
4
5
6
7
8
9
10
75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnd-frc2-e

Table of Contents