Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 216

Table of Contents

Advertisement

Error code (HEX)
An error occurred when
0x01808301
receiving data.
0x01808401
0x01808402
0x01808403
0x0180840F
0x01808410
The communication line cannot
0x01808405
be opened.
0x01808406
0x01808407
0x01808408
0x01808409
0x0180840A
Error message
• FR-A800-E/F800-E
The function to communicate with
FR Configurator2 is not set in
Pr.1427 to Pr.1429 Ethernet
function selection.
• FR-A800-E-R2R
The function to communicate with
FR Configurator2 is not set in
Pr.1076 to Pr.1078 Ethernet
function selection.
• FR-E800-E
The function to communicate with
FR Configurator2 is not set in
Pr.1427 to Pr.1430 Ethernet
function selection.
• FR-E700-NE
The function to communicate with
FR Configurator2 is not set in
Pr.833 to Pr.835 Ethernet
function selection.
Control error.
Signal cable control error.
Incorrect signal cable setting.
Failed to obtain the signal cable
status information.
CD signal cable offline.
Communication parameter setting
error.
Incorrect baud rate setting.
Incorrect data length setting.
Incorrect parity setting.
Incorrect stop bit setting.
Communication setting error.
Possible cause
"Ethernet" is selected from the "PC-side
port" drop-down list and "Not used" from the
"Through" drop-down list.
• FR-A800-E/F800-E
Set the combination of "5001" (or
"5002") and "45237" in any two
parameters from Pr.1427 to
Pr.1429.
• FR-A800-E-R2R
Set the combination of "5001" (or
"5002") and "45237" in any two
parameters from Pr.1076 to
Pr.1078.
• FR-E800-E
Set the combination of "5001" (or
"5002") and "45237" in any two of
Pr.1427 to Pr.1430.
• FR-E700-NE
Set the combination of "31" (or "32")
and "20" in any two parameters from
Pr.833 to Pr.835.
"GOT" is selected from the "Through" drop-
down list and the GOT and the inverter are
connected via Ethernet.
• FR-A800-E/F800-E
Set "5001", "5000", "5006", or
"5008" in any parameter from
Pr.1427 to Pr.1429.
• FR-A800-E-R2R
Set "5001", "5000", "5006", or
"5008" in any parameter from
Pr.1076 to Pr.1078.
• FR-E800-E
Set "5001", "5000", "5006", or
"5008" in any parameter from
Pr.1427 to Pr.1430.
• FR-E700-NE
Set "31", "30", "36", or "38" in any
parameter from Pr.833 to Pr.835.
"Programmable controller" or "GOT to
programmable controller" is selected from
the "Through" drop-down list.
• FR-A800-E/F800-E
Set "5001" in any parameter from
Pr.1427 to Pr.1429.
• FR-A800-E-R2R
Set "5001" in any parameter from
Pr.1076 to Pr.1078.
• FR-E800-E
Set "5001" in any of Pr.1427 to
Pr.1430.
• FR-E700-NE
Set "31" in any parameter from
Pr.833 to Pr.835.
Check the communication
environment.
Check the communication settings.
Countermeasure
215
4. TROUBLE INDICATION