• Since the communication-related parameters are also converted, communication may be disabled depending on the
setting after the setting is written to parameters.
Pr.117 to Pr.124: PU connector communication
Pr.442 to Pr.445, Pr.1424 to Pr.1432, Pr.1434 to Pr.1455: Ethernet communication
Pr.547, Pr.548: USB communication
• When the SF-PR motor is used, set "70 or 73" in Pr.71 Applied motor or Pr.450 Second applied motor after conversion.
• To disable the PWM carrier frequency automatic reduction function after conversion to avoid the change in the motor
driving sound, set "0" in Pr.260 PWM frequency automatic switchover. To enable the PWM carrier frequency automatic
reduction function, set "10".
• After conversion, initial values are set in the following parameters. The settings are equivalent to those in the FR-E700.
Change the settings as required.
Pr.639 Brake opening current selection
Pr.640 Brake operation frequency selection
• When output shutoff is intended when the Ethernet board fails in the source inverter (FR-E700-NE), set "0" in Pr.502 Stop
mode selection at communication error after conversion.
• The setting value of Pr.850 Ethernet TCP disconnection time coefficient in the source inverter (FR-E700-NE) will be
converted to the setting value of Pr.1455 Keepalive time in the target inverter (FR-E800) after conversion. To use Ethernet
TCP, check the Pr.1455 setting.
• When "2" is set in Pr.30 of the source inverter (FR-E700), check the Pr.30 setting in the target inverter (FR-E800-SCE)
after conversion.
• The following parameters are not converted because the FR-E800 series inverters have no corresponding parameters.
Pr.146 Built-in potentiometer switching
Pr.922 Frequency setting voltage bias frequency (built-in potentiometer)
Pr.923 Frequency setting voltage gain frequency (built-in potentiometer)
Pr.387 Initial communication delay time
Pr.388 Transmission interval during heartbeat
Pr.389 Minimum transmission time during heartbeat
Pr.391 Reception interval during heartbeat
Pr.392 Event-driven detection width
*1
Available when the plug-in option is connected.
• After conversion, set the voltage/current input switch according to the Pr.73 Analog input selection and Pr.267 Terminal
4 input selection settings in the FR-E800 inverter.
• When "68" is set in Pr.190 to Pr.192 (Output terminal function selection) in the FR-E700 inverter, set initial values in
Pr.190 to Pr.192 after conversion in the FR-E800 inverter that does not support the FR-E8DS.
*1
*1
*1
*1
*1
1
2
3
4
5
6
7
8
9
10
129
3. FUNCTION
3.3 Convert

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnd-frc2-e

Table of Contents