Iqss Backup File Conversion Function; Iqss Backup File Conversion - Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual

Table of Contents

Advertisement

3.13

iQSS backup file conversion function

The iQSS backup file conversion function is not available for the following models.
Model: FR-E800(-E/-SCE), FR-CS80, FR-A700, FR-B (700), FR-B3 (700), FR-F700, FR-F700P, FR-E700, FR-D700, FR-
E700EX, FR-D700-G, and FR-E500
This is a function to convert a file in the backup/restore format generated by the GOT. The file is converted into the format of
the USB memory parameter copy file or the format that can be opened for the Developer function. To start the iQSS backup
file conversion, choose [iQSS backup file conversion] in the [Tool] menu.

3.13.1 iQSS backup file conversion

In the iQSS backup file conversion dialog, the file format can be converted to the editable file format or the backup/restore
format.
Symbol
Name
A
File location
Format after the
B
conversion
C
Source file
D
Target file
188
3. FUNCTION
3.13 iQSS backup file conversion function
C
Specify the folder in which the file to be converted is stored.
Select "Conversion to editable format" or "Conversion to the backup/restore format".
Conversion to the editable format:
The file is converted into the format that can be used for the USB memory parameter copy or the
Developer function.
Conversion to the backup/restore format:
The file converted for the edit functions is reconverted to the backup/restore format.
The files stored in the selected file location are shown.
If any file is missing, the file name is displayed in gray.
The files after the conversion are shown.
If any file has the same name as the saved file, the file name is displayed in red.
A
B
D
Function/description