 FR-E700 and FR-E700EX
• Applicable cable
Interface
Transmission speed
Wiring length
800 series, FR-E700, and FR-E700EX
Connector
FR-A700, FR-B (700), and FR-B3 (700) USB B connector (B receptacle)
Recommended USB cable
 Related parameters for USB connection
Set the following communication parameter when connecting the USB connector of the inverter. To set parameters or input
operation commands, set the following parameters and switch the operation mode to PU operation mode.
Inverter
FR-A800(-E)
FR-B
FR-B3
FR-B4
FR-F800(-E)
FR-E800(-E/-SCE)
FR-A700
FR-E700(SC)(NC)
FR-E700EX
FR-B (700)
FR-B3 (700)
NOTE
• Set a station number of each inverter in Pr.547 USB communication station number. Perform inverter reset after setting the
parameter.
32
1. OUTLINE
1.4 Connection and parameter setting
USB connector
USB cable
How to open the USB connector cover
Pull the cover in the direction of arrow.
Communication parameter
Pr.548 USB communication check time
interval = "9999" (initial value)
Pr.548 USB communication check time
interval ≠ "0" (initial value: "9999")
Conforms to USB 1.1
12 Mbps
Maximum 5 m
USB mini B connector (receptacle)
MR-J3USBCBL3M (cable length 3 m)
Parameter setting
Command source parameter
Pr.551 PU mode operation
command source selection = "3 or
9999" (initial value: "9999")
Pr.551 PU mode operation
command source selection = "3 or
9999" (initial value: "9999")
Pr.551 PU mode operation
command source selection = "3"
(initial value: "2")
Then turn it upward.