Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 63

Table of Contents

Advertisement

Pr.
1427
Ethernet function selection 1
*1
N630
1428
Ethernet function selection 2
*1
N631
1429
Ethernet function selection 3
*1
N632
1430
Ethernet function selection 4
*1
N633
1434
IP address 1 (Ethernet)
*1
N600
1435
IP address 2 (Ethernet)
*1
N601
1436
IP address 3 (Ethernet)
*1
N602
1437
IP address 4 (Ethernet)
*1
N603
1438
Subnet mask 1
*1
N610
1439
Subnet mask 2
*1
N611
1440
Subnet mask 3
*1
N612
1441
Subnet mask 4
*1
N613
1442
IP filter address 1 (Ethernet)
*1
N660
1443
IP filter address 2 (Ethernet)
*1
N661
1444
IP filter address 3 (Ethernet)
*1
N662
1445
IP filter address 4 (Ethernet)
*1
N663
1446
IP filter address 2 range
*1
specification (Ethernet)
N664
1447
IP filter address 3 range
*1
specification (Ethernet)
N665
1448
IP filter address 4 range
*1
specification (Ethernet)
N666
*1
The setting is applied after an inverter reset or next power-ON.
*2
The setting is available for the FR-E800-E only.
*3
The setting is available only for the FR-E800-EPB and the FR-E800-SCEPB.
• The parameters listed in the following table are not used for connection with the personal computer (FR Configurator2).
Set the parameters according to the application.
Pr.
1320 to
User Defined Cyclic
1329
Communication Input 1 to 10
N810 to
Mapping
*1
N819
62
1. OUTLINE
1.4 Connection and parameter setting
Name
Initial value
5001
45237
45238
9999
192
168
50
1
255
255
255
0
0
0
0
0
9999
9999
9999
Name
Initial value
9999
Setting range
502, 5000 to 5002,
5006 to 5008, 5010
to 5013, 9999,
Set the application, protocol, and so on.
*3
*2
34962
, 44818
,
45237, 45238,
*2
47808
, 61450
Enter the IP address of the inverter to be connected to
0 to 255
Ethernet.
Enter the subnet mask of the network to which the
0 to 255
inverter belongs.
0 to 255
Set the range of connectable IP addresses for the
network devices. (When Pr.1442 to Pr.1445 = "0 (initial
value)", the function is invalid.)
0 to 255, 9999
Setting range
*2
*2
5
, 100
, 12288 to
13787, 20488,
Set the index number for inverter parameters, inverter
20489, 24672,
control parameters, and CiA402 drive profile. Functions
24689, 24698,
can be assigned to remote registers RWwn+4 to
24703, 24705,
RWwn+17 when Pr.544 = "38".
24707, 24708,
24719, 24721,
24728 to 24730
9999
Function disabled
Description
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnd-frc2-e

Table of Contents