Running The Inverter In Test Operation (Forward Rotation, Reverse Rotation, And Stop Commands) - Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual

Table of Contents

Advertisement

3.9.4
Running the inverter in test operation (forward
rotation, reverse rotation, and stop commands)
Press the [Forward rotation] or [Reverse rotation] button to execute test operation. Press the STOP button to stop operation.
Selecting "Operate while the Forward rotation or Reverse rotation button is pressed" will execute test operation only while the
[Forward rotation] or [Reverse rotation] button is held down. Simply pressing the [Forward rotation] or [Reverse rotation] button
will write the input frequency value to the inverter. After the value is written to the inverter, the test operation will start. Release
the [Forward rotation] or [Reverse rotation] button to stop the operation.
Symbol
Name
A
Forward rotation
B
Reverse rotation
C
Stop
D
Operation option
NOTE
• Open the batch monitor window (on
• If FR Configurator2 had to be terminated, stop the operation by sending an operation stop command to the inverter.
• Do not press an individual operation button, such as [Forward rotation] or [Reverse rotation], repeatedly. Doing so may make
the FR Configurator2 operation unstable. If operation continues unintentionally, press [Stop] to stop operation.
• Operation may continue without the [Forward rotation] or [Reverse rotation] button being held down by dragging the mouse
cursor off the button while holding down the [Stop] button. Press the [Stop] button to stop operation.
• The [Forward rotation] and [Reverse rotation] buttons are disabled when the computer is connected with the inverter via CC-
Link IE network communication.
Caution
• If communication fails (due to, for example, cable disconnection), the inverter cannot be stopped from the personal
computer.
Ensure safety by, for example, enabling signal loss detection (Pr.122, Pr.336, Pr.548, Pr.851, Pr.852, Pr.1431, or
Pr.1432) or externally setting a stop device.
• Test operation is not properly performed when the computer is connected to the inverter via CC-Link IE Field Network
communication.
166
3. FUNCTION
3.9 Test Operation
A
D
Function/description
Rotates the motor forward.
Rotates the motor reversely.
Stops the operation.
Click on the checkbox to enable test operation only while the [Forward rotation] or [Reverse
rotation] button is held down.
page
149) to check the output frequency during test operation.
C
B