Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 62

Table of Contents

Advertisement

*2
Parameters which can be displayed when this plug-in option (FR-A8NCG) is installed.
*3
The initial value after All parameter clear with the FR-A8NCG installed.
 IP address setting
• For CC-Link IE TSN communication, the IP address of the inverter is set using the station number switches on the
communication circuit board of the FR-A8NCG or inverter parameters. Note that the station number switch
higher priority than the parameter setting. (When the station number switches are not set to "0 or 255", the station number
switch setting has a higher priority than the Pr.437 setting.) For CC-Link IE TSN communication, the third octet of the
inverter's IP address is used as the network No. and the fourth octet is used as the station number. (Enter the IP address
assigned by the network administrator.)
*1
For details on the station number switches, refer to the CC-Link IE TSN Function Manual or FR-A8NCG Instruction Manual.
 Setting the IP address with the station number switches
• Set a value other than "0 (H00)" or "255 (HFF)" to specify a station number using the station number switches. The setting
range is from "1 (H01)" to "254 (HFE)". The setting is applied after an inverter reset or at the next power-ON.
IP address
First octet
The settings of the master station are used. (The settings from Pr.434 to Pr.436
Second octet
are invalid.)
Third octet
Fourth octet
The station number switch setting is enabled regardless of the setting in Pr.437.
 Setting the IP address with parameters (Pr.434 to Pr.437)
• Set the station number switches to "0 (H00)" or "255 (HFF)" to specify the IP address of the inverter using Pr.434 to Pr.437.
The setting is applied after an inverter reset or at the next power-ON.
IP address
Description
First octet
Pr.434
Second octet
Pr.435
Third octet
Pr.436
Fourth octet
Pr.437
• Enter the inverter network number in Pr.436 IP Address 3.
• The setting range of Pr.436 is "0 to 255", but its active range is "1 to 254". The values out of the active range are invalid
because such values cannot be transmitted to the master station.
• Specify the inverter station number in Pr.437 IP Address 4.
• The setting range of Pr.437 is "0 to 255", but its active range is "1 to 254". Out-of-range setting values are invalid because
such values cannot be transmitted to the master station.
 Related parameters for connection using CC-Link IE TSN (for FR-E800-
(SC)E inverter)
• For details on CC-Link IE TSN communication, refer to the FR-E800 Instruction Manual (Communication).
Pr.
Name
541
Frequency command sign
N100
selection
544
CC-Link extended setting
*1
N103
1424
Ethernet communication
*1
network number
N650
1425
Ethernet communication
*1
station number
N651
1426
Link speed and duplex mode
*1
selection
N641
Description
Initial value
Setting range
0
0
1
0, 1, 12, 14, 18, 38,
0
100, 112, 114, 118,
138
1
1 to 239
1
1 to 120
0
0 to 4
Description
Signed frequency command value
Unsigned frequency command value
Use this parameter to extend the function of the remote
registers for the CC-Link IE TSN.
Enter the network number.
Enter the station number.
Set the communication mode (full-duplex/half-duplex).
1.4 Connection and parameter setting
1
*1
setting has a
2
3
4
5
6
7
8
9
10
61
1. OUTLINE