• FR-E800-(SC)E
For details on CC-Link IE TSN communication, refer to the FR-E800 Instruction Manual (Communication).
Pr.
541
Frequency command sign
N100
selection
544
CC-Link extended setting
*1
N103
1426
Link speed and duplex mode
*1
selection
N641
1442
IP filter address 1 (Ethernet)
*1
N660
1443
IP filter address 2 (Ethernet)
*1
N661
1444
IP filter address 3 (Ethernet)
*1
N662
1445
IP filter address 4 (Ethernet)
*1
N663
1446
IP filter address 2 range
*1
specification (Ethernet)
N664
1447
IP filter address 3 range
*1
specification (Ethernet)
N665
1448
IP filter address 4 range
*1
specification (Ethernet)
N666
804
Torque command source
D400
selection
810
Torque limit input method
H700
selection
*1
The setting is applied after an inverter reset or next power-ON.
• The parameters listed in the following table are not used for connection with the personal computer (FR Configurator2).
Set the parameters according to the application.
Pr.
1320 to
User Defined Cyclic
1329
Communication Input 1 to 10
N810 to
Mapping
*1
N819
1330 to
User Defined Cyclic
1343
Communication Output 1 to 14
N850 to
Mapping
*1
N863
User Defined Cyclic
*1
Communication Input Sub 1
1389
and 2 Mapping
User Defined Cyclic
*1
Communication Input Sub 3
1390
and 4 Mapping
46
1. OUTLINE
1.4 Connection and parameter setting
Name
Initial value
0
0
0
0
0
0
0
9999
9999
9999
0
0
Name
Initial value
9999
9999
0
0
Setting range
0
Signed frequency command value
1
Unsigned frequency command value
0, 1, 12, 14, 18,
Use this parameter to extend the function of the remote
100, 112, 114, 118
registers for the CC-Link IE TSN.
0 to 4
Set the communication mode (full-duplex/half-duplex).
0 to 255
Set the range of connectable IP addresses for the
network devices. (When Pr.1442 to Pr.1445 = "0 (initial
value)", the function is invalid.)
0 to 255, 9999
In the torque control mode, the torque command source
0, 1, 3 to 6
can be selected.
0 to 2
The torque limit input method can be selected.
Setting range
*3
*3
5
, 100
, 12288 to
13787, 20488,
Set the index number for inverter parameters, inverter
20489, 24672,
control parameters, and CiA402 drive profile. Functions
24689, 24698,
can be assigned to remote registers RWwn+4 to
24703, 24705,
RWwn+17 when Pr.544 = "38".
24707, 24708,
24719, 24721,
24728 to 24730
9999
Function disabled
*3
*3
6
, 101
, 12288 to
13787, 16384 to
16483, 20488,
20489, 20981 to
Set the index number for inverter parameters, monitor
*2
20990, 20992
,
data, inverter control parameters, and CiA402 drive
24639, 24643,
profile. Functions can be assigned to remote registers
24644, 24673 to
RWrn+4 to RWrn+1F when Pr.544 = "38".
24676, 24692,
24695, 24820,
24826, 24828,
25858
9999
Function disabled
Pr.1389 (lower 8 bits): Subindex to which the index
0 to 2, 256 to 258,
number is specified using Pr.1320Pr.1389 (upper 8 bits):
512 to 514
Subindex to which the index number is specified using
Pr.1321
Pr.1390 (lower 8 bits): Subindex to which the index
0 to 2, 256 to 258,
number is specified using Pr.1322Pr.1390 (upper 8 bits):
512 to 514
Subindex to which the index number is specified using
Pr.1323