How to Program

2.1.5 Parameter Set-up

The frequency converter can be used for practically all
assignments. The frequency converter offers an option
between 2 programming modes:
Main menu mode.
Quick menu mode.
Main menu provides access to all parameters. Quick menu
takes the user through a few parameters, making it
possible to start operating the frequency converter.
Change a parameter in either main menu mode or quick
menu mode.

2.1.6 Quick Menu Key Functions

Press [Quick Menu] to enter a list of different areas
contained in the Quick Menu.
Illustration 2.13 Quick Menus
Select Quick Start to go through a selection of parameters
to get the motor running almost optimally. The default
setting for the other parameters considers the required
control functions and the configuration of signal inputs/
outputs (control terminals).
The parameter selection is effected with the navigation
keys. The parameters in Table 2.2 are accessible.
Parameter
Parameter K-01 Language
Parameter K-02 Motor Speed Unit
Parameter P-02 Motor Power [HP]
or
Parameter P-07 Motor Power [kW]
Parameter F-05 Motor Rated Voltage
Parameter P-03 Motor Current
Parameter F-04 Base Frequency
Parameter P-06 Base Speed
Parameter F-01 Frequency Setting 1
Parameter F-02 Operation Method
Parameter F-07 Accel Time 1
Parameter F-08 Decel Time 1
Parameter F-10 Electronic Overload
DET-618D
AF-650 GP™ Programming Guide
Parameter
Parameter F-17 Motor Speed High Limit
[RPM]
or
Parameter F-15 Motor Speed High Limit
[Hz]
Parameter F-18 Motor Speed Low Limit
[RPM]
or
Parameter F-16 Motor Speed Low Limit
[Hz]
Parameter H-08 Reverse Lock
Parameter P-04 Auto Tune
Table 2.2 Selection of Parameter
Select Parameter Data Check to get information about:
Select Trendings to get information about the display line
readouts. The information is shown as graphs.
Only parameters selected in parameter K-20 Display Line 1.1
Small and parameter K-24 Display Line 3 Large can be
viewed. It is possible to store up to 120 samples in the
memory for later reference.
Setting
[kW]
[V]
[A]
[Hz]
[RPM]
[s]
[s]
02/2016 All rights reserved.
The last 10 changes. Use the [
keys to scroll between the last 10 changed
parameters.
The changes made since default setting.
Setting
2
[1] Enable complete
Auto Tune
] [