Advertisement

Parameter Descriptions
DR-52 Feedback[Unit]
Range:
DR-53 Digi Pot Reference
Range:
Function:
0
[-200 - 200] View the contribution of the digital potenti-
*
ometer to the actual reference.
DR-57 Feedback [RPM]
Range:
Function:
0 RPM
[-30000 -
Readout parameter where the actual motor
*
30000 RPM]
RPM from the feedback source can be read
in both closed loop and open loop. The
feedback source is selected by
parameter PI-00 Speed PID Feedback Source.
3.18.5 DR-6# Inputs/Outputs
Parameters to view the digital and analog I/O status values.
DR-60 Digital Input
Range:
Function:
0
[0 -
View the signal states from the active digital
*
1023]
inputs. Example: Input 18 corresponds to bit
number 5, 0 = no signal, 1 = connected signal.
Bit 0
Digital input terminal 33.
Bit 1
Digital input terminal 32.
Bit 2
Digital input terminal 29.
Bit 3
Digital input terminal 27.
Bit 4
Digital input terminal 19.
Bit 5
Digital input terminal 18.
Bit 6
Digital input terminal 37.
Bit 7
Digital input General Purpose I/O
OPCGPIO terminal X30/4 (OPCGPIO).
Bit 8
Digital input General Purpose I/O
OPCGPIO terminal X30/3 (OPCGPIO).
Bit 9
Digital input General Purpose I/O
OPCGPIO terminal X30/2 (OPCGPIO).
Bit 10–63
Reserved for future terminals.
Table 3.25 Active Digital Inputs
DET-618D
AF-650 GP™ Programming Guide
Function:
Feedback Unit,
parameter F-52 Minimum
Reference, and
parameter F-53 Maximum
Reference.
02/2016 All rights reserved.
DR-60 Digital Input
Range:
Function:
Illustration 3.43 Relay Settings
DR-61 Terminal 53 Switch Setting
Option:
Function:
View the setting of input terminal 53.
[0]
Current
*
[1]
Voltage
DR-62 Analog Input 53
Range:
Function:
0
[-20 - 20]
View the actual value at input 53.
*
DR-63 Terminal 54 Switch Setting
Option:
Function:
View the setting of input terminal 54.
[0]
Current
*
[1]
Voltage
DR-64 Analog Input 54
Range:
Function:
0
[-20 - 20]
View the actual value at input 54.
*
DR-65 Analog Output 42 [mA]
Range:
Function:
0
[0 - 30] View the actual value at output 42 in mA. The
*
value shown reflects the selection in
parameter AN-50 Terminal 42 Output.
DR-66 Digital Output [bin]
Range:
Function:
0
[0 - 15]
View the binary value of all digital outputs.
*
DR-67 Freq. Input #29 [Hz]
Range:
Function:
0
[0 - 130000] View the actual frequency rate on terminal 29.
*